NW115 F Fire Resisting Wall
Alco Beldan NW115 F Fire Resisting Wall
Our type NW115 F is a movable partition wall which has been tested in accordance with DIN 4102-T2 and achieved 60 minutes with class A2 (non-flammable) cladding boards.
This was also tested with B2 (normal) cladding boards and achieved 30 minutes.
The same construction was also tested for sound reduction and achieved ratings up to Rw 54dB in accordance with EN 20140-3 (1995). This type NW115F is also smoke resistant to DIN 18095-2
The Alco Beldan NW115F has been tested in accordance with DIN EN 1364-1 classification and General Building Control Test Certificates have been issued for 30 minutes and 60 minutes fire resistance.
The sample tested included several inter-panel joints, grooves, fixings, wall posts etc. This is therefore a fully movable partition wall which when fully closed and locked in position, achieved the same fire resistance as a fixed wall.
The NW115 F movable wall system meets the requirements of the Building Regulations and currently represents the best movable partition wall for the protection of escapes and rescue routes.
Specification
- Panel choice:
- Similar to NW100 but No glazing cut-outs No lip seal joints No door panels (not tested)
- Panel thickness:
- 115mm
- Internal Frame:
- Peripheral welded steel section as NW100
- Panel cladding:
- 16mm boards rated A2 or B2 depending upon fire rating required.
- Finishes:
- Laminate, veneer or paint (max thickness 0.5mm)
- Inter-panel joints:
- Aluminium profiles with magnetic inserts as NW100
- Vertical edge profiles:
- Concealed type CP only
- Acoustic seals:
- Special seals with in tumescent strips at top and bottom
- Seal operation:
- As NW100
- Track:
- G M Steel with special protective track cladding
- Sound insulation:
- Rw 49dB up to Rw 54dB (laboratory tested in accordance with ISO/EN 140-3 1995).
There is no reason specifiers should be put off insisting on inspecting a copy of the test data as vague covering statements such as “testing in accordance with DIN 4102 F30 quality” or “F30 A/B flammability” means nothing.